Search results

Jump to navigation Jump to search

Page title matches

  • #REDIRECT [[EMO:Viewing SFT Constraints in EMO]]
    48 bytes (7 words) - 14:09, 12 February 2014
  • ...and displays the following data about each Auto-SFT constraint created by EMO. :Name of the Auto-SFT constraint created by EMO during dispatch
    1 KB (160 words) - 14:39, 11 April 2014

Page text matches

  • ...eforehand. But what constraints will there be in the market at that point in time? Is history a good guide? ...therto not observed in published market data, and this is where EMO's Auto-SFT feature can help.
    1 KB (233 words) - 08:28, 12 February 2016
  • ...be needed if a line is added to a forecast and needs to be included in the SFT modelling. ...pears from which an existing line can be chosen to provide starting values in the calculator. Once the calculator is open the conductor properties and t
    750 bytes (132 words) - 08:48, 12 February 2016
  • The '''Circuits Tab''' in the '''''[[EMO:Main Window Display Panel|Main Window Display Panel]]'''''. :Indicates the Circuit is included in the HVDC Modelling when checked
    2 KB (332 words) - 13:35, 26 February 2016
  • ...fer (EMO) Wiki. This wiki contains the help information for Energy Link's EMO model of the New Zealand electricity spot market. EMO is a full market clearing engine which also includes the ability to view th
    1 KB (185 words) - 13:47, 7 February 2014
  • '''>> To load Transmission data in to your forecast Definition:''' #Click the '''Load Data button''' (or use the '''Data > Load Data''' option in the Menu bar of the '''''Forecast Definition Window''''' to open the '''''L
    3 KB (369 words) - 15:02, 26 February 2016
  • :Selects what type of data is displayed in the Display Area and opens Secondary Information Windows **Equation Constraints
    1 KB (154 words) - 14:52, 11 April 2014
  • == SFT constraints in SPD == ...PD. These constraints are designed to avoid thermal overloading of a line in the event of the unexpected outage of any other line.
    5 KB (823 words) - 08:02, 21 December 2015
  • ...the Forecast Definition. Checking this box makes the Reserves tab visible in the Summary Panel :''Auto-SFT Check Box''
    847 bytes (114 words) - 15:08, 12 February 2014
  • The Data Type Selector Tab at the top of the '''''[[EMO:Main Window Display Panel|Main Window Display Panel]]'''''. To display textual data for the following data types in the Main Window Display Area:
    4 KB (643 words) - 12:58, 13 February 2014
  • ...to us, so there is an inevitable degree of approximation in estimating SFT constraints from our point of view. ...t \(( \underline{C}, \underline{C} )\), and \(\alpha\), the rate of change in that slope with respect to \(F_{m}\).
    4 KB (685 words) - 12:51, 18 December 2015
  • ...olved. The information required by EMO to do this derivation is contained in two files, the Conductor Parameters file and the Circuit Configuration file ...a file with the correct name format into a directory at <Data>/Inputs/Grid/SFT/Manual.
    3 KB (495 words) - 13:03, 21 December 2015
  • ...ata through a powerful set of information presentation tools in the '''''[[EMO:The Presentation Interface|Presentation Interface]]''''' ...enerally termed Forecasting) and presenting the results through the '''''[[EMO:The Presentation Interface|Presentation Interface]]'''''
    2 KB (328 words) - 08:42, 10 February 2014
  • The ''EMarketOffer'' '''''[[EMO:The Presentation Interface|Presentation Interface]] '''''provides four gene *Transmission System configuration including Branch Constraints
    4 KB (564 words) - 09:00, 11 February 2014
  • * '''Market View''' - view the market outcome for a half hour on the EMO map ...one trading period, in the same way as the SPD market clearing engine used in the New Zealand wholesale electricity Market, and conduct what-if scenario
    2 KB (299 words) - 08:38, 10 February 2014
  • ...t be stored in the local machine in relational database schema implemented in either Microsoft Access or SQL server. ...d. Forecast files can subsequently exported to networked locations either in native XML format or translated into csv format.
    4 KB (541 words) - 09:05, 10 February 2014
  • =Latest Release EMO 5.2.20 released February 2016= ...efore seen" SFT constraints in future scenarios that may not have occurred in the past.
    22 KB (3,723 words) - 11:51, 3 March 2016