ifference between revisions of "EMO:Loaded Circuits"
(Created page with "{{#hidens:}}") |
|||
Line 1: | Line 1: | ||
{{#hidens:}} | {{#hidens:}} | ||
+ | === Items === | ||
+ | {|class="wikitable" | ||
+ | ! Item !! Purpose | ||
+ | |- | ||
+ | | | ||
+ | :''Circuit Name'' | ||
+ | | | ||
+ | :Name of Circuit | ||
+ | |- | ||
+ | | | ||
+ | :''FromNode'' | ||
+ | | | ||
+ | :Circuit 'From' Node | ||
+ | |- | ||
+ | | | ||
+ | :''ToNode'' | ||
+ | | | ||
+ | :Circuit 'To' Node | ||
+ | |- | ||
+ | | | ||
+ | :''isHVDC'' | ||
+ | | | ||
+ | :Component of HVDC indicator (checked when circuit contributes to the HVDC link) | ||
+ | |- | ||
+ | | | ||
+ | :''Resistance'' | ||
+ | | | ||
+ | :Circuit Resistance value | ||
+ | |- | ||
+ | | | ||
+ | :''Reactance'' | ||
+ | | | ||
+ | :Circuit Reactance value | ||
+ | |- | ||
+ | | | ||
+ | :''Summer Capacity'' | ||
+ | | | ||
+ | :Circuit Summer Capacity | ||
+ | |- | ||
+ | | | ||
+ | :''Winter Capacity'' | ||
+ | | | ||
+ | :Circuit Winter Capacity | ||
+ | |- | ||
+ | | | ||
+ | :''Re-Rated'' | ||
+ | | | ||
+ | :Checked when circuit is re-rated at any time during the Forecast Effective Date Range | ||
+ | |} | ||
+ | |||
+ | |||
+ | NOTES: | ||
+ | #The values of all fields in the Grid can be edited except for the Re-Rating indicator which is read-only and the Circuit Name which can only be changed using the Edit Circuit Window. | ||
+ | #''EMarketOffer'' flags a Circuit as re-rated if the Branch Constraint data file contains a rating change for the Circuit that starts before or during the Forecast Effective Date Range and that ends during or after the Effective Date Range. Many such re-ratings are for prolonged durations, and it is quite likely to see a Circuit flagged as re-rated and unchanging throughout the Forecast Effective Date Range. | ||
+ | |||
+ | |||
+ | === Grid Features === | ||
+ | Double-click on a row to open the associated '''''Edit Circuit Window''''' where Circuit details can be edited. | ||
+ | |||
+ | <span style="color:#2E5894"> | ||
+ | '''>> To add a new Circuit:''' | ||
+ | #Click on any row in the Circuits Data Grid and press the ''<Insert>'' key. This creates an empty row at the top of the Grid labelled " _ new _ ". Details of the Circuit can be entered by bringing up the '''''Edit Circuit Window''''' by double-clicking the empty row. | ||
+ | |||
+ | <span style="color:#2E5894"> | ||
+ | '''>> To delete an existing Circuit:''' | ||
+ | #Click on the row in the Circuit Data Grid containing the Circuit you want to delete and press the ''<Delete>'' key. A dialogue box asking you to confirm the delete operation will appear. | ||
+ | |||
+ | |||
+ | NOTE: Deleting a Circuit also deletes any re-ratings data associated with the Circuit at the time of deletion | ||
+ | |||
+ | |||
+ | === The Edit Circuits Window === | ||
+ | |||
+ | ==== Access ==== | ||
+ | Double-clicking a Circuit Name in the '''''Loaded Data Summary Panel''''' of either the '''''Forecast Definition''''' or '''''Powerflow Case Definition''''' Windows. | ||
+ | |||
+ | ==== Purpose ==== | ||
+ | To manually enter and modify a Circuit's '''''Static Data''''' and also add, delete or change re-ratings occurring during the Forecast Effective Date Range. | ||
+ | |||
+ | ==== Features ==== | ||
+ | {|class="wikitable" | ||
+ | ! Feature !! Description | ||
+ | |- | ||
+ | | | ||
+ | :''Name'' | ||
+ | | | ||
+ | :Used to identify any Circuit data used in the Definition. When loaded from file the Circuit name defaults to that used by Transpower which uses a FROM_TO.NUMBER naming convention. However, the field is used for description only and can be renamed without affecting how the system deals with the Circuit. | ||
+ | |- | ||
+ | | | ||
+ | :''From'' | ||
+ | | | ||
+ | :The Circuit 'From' Node. The relationship between the 'From' and 'To' Nodes does not affect how ''EMarketOffer'' calculates Powerflows. However, the relationship is important as flows are displayed on the map and information Windows as +ve if flow is towards the 'To' Node and -ve if flow is towards the 'From' Node. | ||
+ | |- | ||
+ | | | ||
+ | :''To'' | ||
+ | | | ||
+ | :The Circuit 'To' Node | ||
+ | |- | ||
+ | | | ||
+ | :''IsHVDC'' | ||
+ | | | ||
+ | :The Circuit is part of the HVDC | ||
+ | |- | ||
+ | | | ||
+ | :''Resistance'' | ||
+ | | | ||
+ | :Circuit resistance | ||
+ | |- | ||
+ | | | ||
+ | :''Reactance'' | ||
+ | | | ||
+ | :Circuit reactance | ||
+ | |- | ||
+ | | | ||
+ | :''Summer'' | ||
+ | | | ||
+ | :Maximum Summer capacity rating. The Summer Rating applies to periods 15 to 42 from 20 October to 8 May | ||
+ | |- | ||
+ | | | ||
+ | :''Shoulder'' | ||
+ | | | ||
+ | :Maximum shoulder capacity rating | ||
+ | |- | ||
+ | | | ||
+ | :''Winter'' | ||
+ | | | ||
+ | :Maximum Winter capacity rating | ||
+ | |- | ||
+ | | | ||
+ | :''Re-Rated Check Box'' | ||
+ | | | ||
+ | :Indicates if the Circuit was re-rated during the Effective Date Range | ||
+ | |- | ||
+ | | | ||
+ | :''Capacity Re-Ratings Grid'' | ||
+ | | | ||
+ | *Date From - Date from which the re-rating will be effective | ||
+ | *TP From - Trading Period from which the re-rating will be effective | ||
+ | *Date To - Date until and including which the re-rating will be effective | ||
+ | *TP To - Trading Period until and including which the re-rating will be effective | ||
+ | *Re-Rating Value - The Circuit capacity in MW effective during the re-rating period. NOTE: A circuit Outage can be modelled as a re-rating of 0 MW for the outage period | ||
+ | |} | ||
+ | |||
+ | |||
+ | NOTE: When uploading historic Transmission System data from EM6/COMIT files ''EMarketOffer'' automatically applies any Transpower notified Branch Constraints. These can be seen as re-ratings in the Circuit Re-ratings grid. | ||
+ | |||
+ | |||
+ | [[EMO:EMarketOffer User Manual|Home]] - [[EMO:Loaded Data Summary Panel|Back]] |
Revision as of 16:10, 24 January 2013
Items
Item | Purpose |
---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTES:
- The values of all fields in the Grid can be edited except for the Re-Rating indicator which is read-only and the Circuit Name which can only be changed using the Edit Circuit Window.
- EMarketOffer flags a Circuit as re-rated if the Branch Constraint data file contains a rating change for the Circuit that starts before or during the Forecast Effective Date Range and that ends during or after the Effective Date Range. Many such re-ratings are for prolonged durations, and it is quite likely to see a Circuit flagged as re-rated and unchanging throughout the Forecast Effective Date Range.
Grid Features
Double-click on a row to open the associated Edit Circuit Window where Circuit details can be edited.
>> To add a new Circuit:
- Click on any row in the Circuits Data Grid and press the <Insert> key. This creates an empty row at the top of the Grid labelled " _ new _ ". Details of the Circuit can be entered by bringing up the Edit Circuit Window by double-clicking the empty row.
>> To delete an existing Circuit:
- Click on the row in the Circuit Data Grid containing the Circuit you want to delete and press the <Delete> key. A dialogue box asking you to confirm the delete operation will appear.
NOTE: Deleting a Circuit also deletes any re-ratings data associated with the Circuit at the time of deletion
The Edit Circuits Window
Access
Double-clicking a Circuit Name in the Loaded Data Summary Panel of either the Forecast Definition or Powerflow Case Definition Windows.
Purpose
To manually enter and modify a Circuit's Static Data and also add, delete or change re-ratings occurring during the Forecast Effective Date Range.
Features
Feature | Description |
---|---|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: When uploading historic Transmission System data from EM6/COMIT files EMarketOffer automatically applies any Transpower notified Branch Constraints. These can be seen as re-ratings in the Circuit Re-ratings grid.