EMO:Use of line conductor information in SFT
The behaviour of SFT constraints is now derived from information about the thermal characteristics of the lines involved. The information required by EMO to do this derivation is contained in two files, the Conductor Parameters file and the Circuit Configuration file.
Both these files are provided by Energy Link in the automatic downloads made by EMO. They will appear in the /Inputs/Grid/SFT directory. The Circuit Configuration file can be overridden by a manually edited file however. This is done by placing a file with the correct name format into a directory at /Inputs/Grid/SFT/Manual.
Conductor Parameters
The Conductor Parameters file contains information on the properties of the different types of conductors used in transpower lines. This is a csv file with a heading line and the following columns. The file is named 'Conductor_Parameters_<yyyyMMdd>.csv' where <yyyyMMdd> is the creation date. A number of these files may appear together but only the one with the latest date will be loaded.
Column | Meaning |
---|---|
Conductor Code |
|
Conductor Description |
|
Absorbivity |
|
Coefficient of Resistance |
|
Resistance @20 C ohms/km |
|
Mass per unit lemgth gm/cm |
|
Diameter mm |
|
Emissivity |
|
Specific Heat Capacity Cal/g/C |
|
Circuit Configuration
The Circuit Configuration describes the configuration of the circuit with regard to the cable type and number and the offload time used. The file is named 'Circuit Configuration_<yyyyMMdd>.csv' where <yyyyMMdd> is the creation date. A number of these files may appear together but only the one with the latest date will be loaded.
Column | Meaning |
---|---|
Branch Id |
|
Date |
|
Limiting Conductor |
|
Number of Conductors |
|
SFT_Status (Y/N) |
|
Offload time (minutes) |
|
Threshold |
|