ifference between revisions of "EMO:Logical Data Structure"
(35 intermediate revisions by 2 users not shown) | |||
Line 4: | Line 4: | ||
'''''Static Data:''''' Static data describes the Items Modelled in ''EMarketOffer'' (e.g. Generator maximum capacity). | '''''Static Data:''''' Static data describes the Items Modelled in ''EMarketOffer'' (e.g. Generator maximum capacity). | ||
− | '''''Dynamic Data:''''' Dynamic data | + | '''''Dynamic Data:''''' Dynamic data describing the state of the Modelled Items defined by the static data and changes rapidly over time, typically by Trading Period (e.g. Nodal Price) |
==Terminology== | ==Terminology== | ||
− | ''EMarketOffer's'' data design consists of 'things' included in the model, and the characteristics of those 'things'. In this manual the 'things' are called '''Entities''' and their characteristics are called '''Traits.''' Traits may be static or dynamic. | + | ''EMarketOffer's'' data design consists of 'things' (or items) included in the model, and the characteristics of those 'things'. In this manual the 'things' are called '''Entities''' and their characteristics are called '''Traits.''' Traits may be static or dynamic. |
For example the ''Circuit'' Entity can have the static Traits of ''Start Node'' and ''End Node'', and the dynamic Traits of ''Powerflow'' and Loss by Trading Period. | For example the ''Circuit'' Entity can have the static Traits of ''Start Node'' and ''End Node'', and the dynamic Traits of ''Powerflow'' and Loss by Trading Period. | ||
Line 15: | Line 15: | ||
---- | ---- | ||
− | ===Modelled | + | ===Modelled Entities=== |
− | Four broad categories of | + | Four broad categories of entity are modelled in ''EMarketOffer:'' |
{|class="wikitable" | {|class="wikitable" | ||
− | ! | + | ! Entity Type !! Relate To |
|- | |- | ||
| | | | ||
Line 41: | Line 41: | ||
|} | |} | ||
− | == System | + | == System Entities== |
− | The following table lists and describes the System | + | The following table lists and describes the System entities modelled in ''EMarketOffer.'' |
{|class="wikitable" | {|class="wikitable" | ||
− | ! | + | ! Entity !! Description !! Attribute (Trait) |
|- | |- | ||
! | ! | ||
Line 78: | Line 78: | ||
Branch Constraint | Branch Constraint | ||
| | | | ||
− | :A Transpower defined Constraint affecting a single Circuit | + | :A Transpower defined Constraint affecting a single Circuit (by imposing a limit on power transfer on the circuit) |
| | | | ||
*Name | *Name | ||
Line 89: | Line 89: | ||
Equation Constraint | Equation Constraint | ||
| | | | ||
− | :A Transpower defined Constraint | + | :A Transpower defined Constraint involving more than one circuit |
| | | | ||
*Name | *Name | ||
Line 106: | Line 106: | ||
|} | |} | ||
− | + | == Market Entities== | |
− | == Market | + | The following table lists and describes the Market entities modelled in ''EMarketOffer'' |
− | The following table lists and describes the Market | ||
{|class="wikitable" | {|class="wikitable" | ||
− | ! | + | ! Entity !! Description !! Attribute (Trait) |
|- | |- | ||
! | ! | ||
Line 137: | Line 136: | ||
|} | |} | ||
− | + | == Commercial Entities == | |
− | == Commercial | + | The following table lists and describes the Commercial entities modeled in ''EMarketOffer'' |
− | The following table lists and describes the Commercial | ||
{|class="wikitable" | {|class="wikitable" | ||
− | ! | + | ! Entity !! Description !! Attribute (trait) |
|- | |- | ||
! | ! | ||
Line 152: | Line 150: | ||
*Unit(s) | *Unit(s) | ||
**Unit Name | **Unit Name | ||
− | **Cost | + | **Cost in dollars per MWh |
*Retail Node(s) | *Retail Node(s) | ||
**Node Name | **Node Name | ||
**Percentage load owned | **Percentage load owned | ||
− | **Retail price | + | **Retail price in dollars per MWh |
*Hedge Contract(s) | *Hedge Contract(s) | ||
**Reference Node name | **Reference Node name | ||
Line 163: | Line 161: | ||
**Hedge end date | **Hedge end date | ||
**Hedge end period | **Hedge end period | ||
− | ** | + | **Strike price in dollars per MWh |
**Quantity (MW) | **Quantity (MW) | ||
|} | |} | ||
− | |||
== Geographical Items == | == Geographical Items == | ||
Line 203: | Line 200: | ||
: ''Powerflow'' | : ''Powerflow'' | ||
| | | | ||
− | :MW | + | :MW |
| | | | ||
|- | |- | ||
Line 209: | Line 206: | ||
:''Price Separation'' | :''Price Separation'' | ||
| | | | ||
− | : | + | :dollars per MWh |
| | | | ||
:Price difference on a constrained Circuit | :Price difference on a constrained Circuit | ||
Line 216: | Line 213: | ||
:''Losses'' | :''Losses'' | ||
| | | | ||
− | : | + | :MW |
| | | | ||
|- | |- | ||
Line 222: | Line 219: | ||
:''Loading'' | :''Loading'' | ||
| | | | ||
+ | :ratio | ||
| | | | ||
− | : | + | :Ratio of flow to capacity |
|- | |- | ||
! rowspan="8" | Company | ! rowspan="8" | Company | ||
Line 236: | Line 234: | ||
:''Generation Revenue'' | :''Generation Revenue'' | ||
| | | | ||
− | : | + | :dollars |
| | | | ||
|- | |- | ||
Line 242: | Line 240: | ||
:''Generation Cost'' | :''Generation Cost'' | ||
| | | | ||
− | : | + | :dollars |
| | | | ||
:Based on Generation marginal cost | :Based on Generation marginal cost | ||
Line 256: | Line 254: | ||
:''Retail Revenue'' | :''Retail Revenue'' | ||
| | | | ||
− | : | + | :dollars |
| | | | ||
|- | |- | ||
Line 262: | Line 260: | ||
:''Retail Cost'' | :''Retail Cost'' | ||
| | | | ||
− | : | + | :dollars |
| | | | ||
:Nodal Price - Retail Price | :Nodal Price - Retail Price | ||
Line 269: | Line 267: | ||
:''Hedge Cash Flow'' | :''Hedge Cash Flow'' | ||
| | | | ||
− | : | + | :dollars |
| | | | ||
:(Nodal Price - Strike Price) * Quantity | :(Nodal Price - Strike Price) * Quantity | ||
Line 276: | Line 274: | ||
:''Total Cash Flow'' | :''Total Cash Flow'' | ||
| | | | ||
− | : | + | :dollars |
| | | | ||
:The sum of all revenues and costs | :The sum of all revenues and costs | ||
Line 324: | Line 322: | ||
:''Price'' | :''Price'' | ||
| | | | ||
− | : | + | :dollars per MWh |
| | | | ||
|- | |- | ||
Line 351: | Line 349: | ||
:''Price'' | :''Price'' | ||
| | | | ||
− | : | + | :dollars per MWh |
| | | | ||
:Across all Region Nodes | :Across all Region Nodes | ||
Line 394: | Line 392: | ||
:''Price Fast Reserve'' | :''Price Fast Reserve'' | ||
| | | | ||
− | : | + | :dollars per MWh |
| | | | ||
:North and South Island | :North and South Island | ||
Line 401: | Line 399: | ||
:''Price Sustained Reserve'' | :''Price Sustained Reserve'' | ||
| | | | ||
− | : | + | :dollars per MWh |
| | | | ||
:North and South Island | :North and South Island | ||
Line 408: | Line 406: | ||
:''DC Offset Fast Reserve'' | :''DC Offset Fast Reserve'' | ||
| | | | ||
− | : | + | :dollars per MWh |
| | | | ||
:North and South Island | :North and South Island | ||
Line 415: | Line 413: | ||
:''DC Offset Sustained Reserve'' | :''DC Offset Sustained Reserve'' | ||
| | | | ||
− | : | + | :dollars per MWh |
| | | | ||
:North and South Island | :North and South Island | ||
Line 422: | Line 420: | ||
:''AC Offset Fast Reserve'' | :''AC Offset Fast Reserve'' | ||
| | | | ||
− | : | + | :dollars per MWh |
| | | | ||
:North and South Island | :North and South Island | ||
Line 429: | Line 427: | ||
:''AC Offset Sustained Reserve'' | :''AC Offset Sustained Reserve'' | ||
| | | | ||
− | : | + | :dollars per MWh |
| | | | ||
:North and South Island | :North and South Island | ||
Line 471: | Line 469: | ||
| | | | ||
:MWh | :MWh | ||
+ | | | ||
+ | :Averaged across all Units | ||
+ | |- | ||
+ | | | ||
+ | :''Price'' | ||
+ | | | ||
+ | :dollars per MWh | ||
+ | | | ||
+ | :Averaged across all Nodes | ||
+ | |- | ||
+ | | | ||
+ | :''Losses'' | ||
+ | | | ||
+ | :MW | ||
| | | | ||
:Averaged across all Nodes | :Averaged across all Nodes | ||
|- | |- | ||
+ | ! rowspan="17" | Unit | ||
| | | | ||
:''Generation'' | :''Generation'' | ||
| | | | ||
− | :MWh | + | :MW |
+ | | | ||
+ | |- | ||
+ | | | ||
+ | :''Fast Reserve dispatched'' | ||
+ | | | ||
+ | :MW | ||
+ | | | ||
+ | |- | ||
+ | | | ||
+ | :''Sustained Reserve dispatched'' | ||
+ | | | ||
+ | :MW | ||
+ | | | ||
+ | |- | ||
+ | | | ||
+ | :''Marginal Indicator'' | ||
+ | | | ||
+ | | | ||
+ | :Indicates if Unit was marginal for the Trading Period in question | ||
+ | |- | ||
+ | | | ||
+ | :''Risk Setter'' | ||
+ | | | ||
+ | | | ||
+ | :Indicates if Unit was setting the risk for the Trading Period in question | ||
+ | |- | ||
+ | | | ||
+ | :''Maximum Generation'' | ||
+ | | | ||
+ | :MW | ||
+ | | | ||
+ | :Maximum generation a unit is capable of producing in the Trading Period (used in Reserves calculation) | ||
+ | |- | ||
+ | | | ||
+ | :''Fast Reserve Offer Quatity (PLSR) bands 1-3'' | ||
+ | | | ||
+ | :MW | ||
+ | | | ||
+ | |- | ||
+ | | | ||
+ | :''Fast Reserve Offer Price (PLSR) bands 1-3'' | ||
+ | | | ||
+ | :dollars per MWh | ||
+ | | | ||
+ | |- | ||
+ | | | ||
+ | :''Fast Reserve RSlope (PLSR) bands 1-3'' | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | | | ||
+ | :''Sustained Reserve Offer Quantity (PLSR) bands 1-3'' | ||
+ | | | ||
+ | :MW | ||
+ | | | ||
+ | |- | ||
+ | | | ||
+ | :''Sustained Reserve Offer Price (PLSR) bands 1-3'' | ||
+ | | | ||
+ | :dollars per MWh | ||
+ | | | ||
+ | |- | ||
+ | | | ||
+ | :''Sustained Reserve RSlope (PLSR) bands 1-3'' | ||
+ | | | ||
+ | | | ||
+ | |- | ||
+ | | | ||
+ | :''Fast Reserve Offer Quantity (TWD/ILR) bands 1-3'' | ||
+ | | | ||
+ | :MW | ||
| | | | ||
− | |||
|- | |- | ||
| | | | ||
− | :''Price'' | + | :''Fast Reserve Offer Price (TWD/ILR) bands 1-3'' |
+ | | | ||
+ | :dollars per MWh | ||
+ | | | ||
+ | |- | ||
| | | | ||
− | : | + | :''Sustained Reserve Offer Quantity (TWD/ILR) bands 1-3'' |
+ | | | ||
+ | :MW | ||
| | | | ||
− | |||
|- | |- | ||
| | | | ||
− | :'' | + | :''Sustained Reserve Offer Price (TWD/ILR) bands 1-3'' |
| | | | ||
− | :MWh | + | :dollars per MWh |
| | | | ||
− | |||
|- | |- | ||
− | |||
| | | | ||
− | : | + | :''Frequency keeping band'' |
+ | | | ||
+ | :MW | ||
+ | | | ||
+ | |} | ||
+ | |||
+ | |||
+ | [[Main Page|Home]] |
Latest revision as of 14:10, 10 February 2014
EMarketOffer uses two broad types of data:
Static Data: Static data describes the Items Modelled in EMarketOffer (e.g. Generator maximum capacity).
Dynamic Data: Dynamic data describing the state of the Modelled Items defined by the static data and changes rapidly over time, typically by Trading Period (e.g. Nodal Price)
Terminology
EMarketOffer's data design consists of 'things' (or items) included in the model, and the characteristics of those 'things'. In this manual the 'things' are called Entities and their characteristics are called Traits. Traits may be static or dynamic.
For example the Circuit Entity can have the static Traits of Start Node and End Node, and the dynamic Traits of Powerflow and Loss by Trading Period.
NOTE: : Static data is not permanently fixed and may, at times, be quite changeable, but within the context of EMarketOffer it is not necessary to be able to track such changes down to the Trading Period level.
Modelled Entities
Four broad categories of entity are modelled in EMarketOffer:
Entity Type | Relate To |
---|---|
|
|
|
|
|
|
|
|
System Entities
The following table lists and describes the System entities modelled in EMarketOffer.
Entity | Description | Attribute (Trait) |
---|---|---|
System Node |
|
|
Substation |
|
|
Circuit |
|
|
Branch Constraint |
|
|
Equation Constraint |
|
|
Reserve Region |
|
|
Market Entities
The following table lists and describes the Market entities modelled in EMarketOffer
Entity | Description | Attribute (Trait) |
---|---|---|
Market Node |
|
|
Unit |
|
|
Generator |
|
|
Commercial Entities
The following table lists and describes the Commercial entities modeled in EMarketOffer
Entity | Description | Attribute (trait) |
---|---|---|
Company |
|
|
Geographical Items
The following table lists and describes the Geographical items modelled in EMarketOffer
Item (entity) | Description | Attribute (trait) |
---|---|---|
Region |
|
|
Note: The Items listed above are not all modelled at the same level in EMarketOffer. For example no distinction is made in the program between System and Market Nodes with Prices being calculated for all System Nodes in Forecasts. Also Branch Constraints are treated as complex attributes of individual circuits rather than Items in their own right.
Dynamic Data
Dynamic data Traits that changes value frequently, typically by Trading Period. The following table lists the dynamic data items modelled in the EMarketOffer:
Modelled Item | Attribute | Units | Comment |
---|---|---|---|
Circuit |
|
|
|
|
|
||
|
|
| |
|
|
||
|
|
| |
Company |
|
|
|
|
|
||
|
|
| |
|
|
| |
|
|
||
|
|
| |
|
|
| |
|
|
| |
Equation Constraint |
|
|
|
|
|
||
|
|
| |
Company |
|
|
|
Node |
|
|
|
|
|
||
|
|
||
|
|
||
Region |
|
|
|
|
|
| |
|
|
| |
|
|
| |
Reserve Region |
|
|
|
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
| ||
|
| ||
Substation |
|
|
|
|
|
| |
|
|
| |
|
|
| |
Unit |
|
|
|
|
|
||
|
|
||
|
| ||
|
| ||
|
|
| |
|
|
||
|
|
||
|
|||
|
|
||
|
|
||
|
|||
|
|
||
|
|
||
|
|
||
|
|
||
|
|