ifference between revisions of "EMO:The File Menu"

From EMO Wiki
Jump to navigation Jump to search
Line 58: Line 58:
 
|
 
|
 
:Reloads all cached data (from file and database)
 
:Reloads all cached data (from file and database)
 +
|}
 +
 +
=== The Grid File Inputs Station Window ===
 +
 +
==== Purpose ====
 +
Details the files currently being used to load Constraints data and any associated loading errors.  The Window can also be used to access and reload external grid files.
 +
 +
==== Components and Features ====
 +
{|class="wikitable"
 +
! Component !! Feature !! Purpose
 +
|-
 +
| rowspan="2" |''Control Panel''
 +
|
 +
:'''Reset Grid Inputs Button'''
 +
|
 +
:Reloads the Constraints data files (allows you to load modified or replaced Transmission System files without having to restart ''EMarketOffer'')
 +
|-
 +
|
 +
:'''Open Grid Files Input Directory Button'''
 +
|
 +
:Opens a standard Windows file directory window ''\Inputs\Grid'' for quick access to Transmission System files
 +
|-
 +
| rowspan="3" | ''Status Panel''
 +
|
 +
:'''External File Types Loaded List'''
 +
|
 +
:Lists type of external transmission systems files loaded (in the above example the EM6 Constraints Change file type has been loaded)
 +
|-
 +
|
 +
:'''Loading Error List'''
 +
|
 +
:List the types of errors found when attempting to load files line by line.  Errors are listed by re-ratings or Group Constraint groupings a total of each is provided.  Errors text for each loading failure are designed to be self-explanatory
 +
|-
 +
|
 +
:'''Setup Error List'''
 +
|
 +
:Lists the errors when attempting to create a consistent set of Constraints after each line has been loaded
 
|}
 
|}

Revision as of 16:21, 11 January 2013

The File Menu provides access to the following EMarketOffer features:

  • Data Sources
  • Map Settings
  • Save All Settings
  • Open EMO Data Directory
  • Exit

The Data Sources Option

Please read in conjunction with the section on Connecting to a Database Server.

Data Source Concepts

Input data can be sourced from file (see Data Files), or from online database servers.

The Database Connection Configuration

EMarketOffer supports multiple connections to multiple database servers. Database connectivity is managed through the Database Connection Configuration (DCC). A DCC contains a number of queries which obtain data from one or more databases. While a DCC's queries can access data in more than one database on more than one database server, it is not possible to have more than one query handling data of the same type (e.g. only one query can return Price data, and only one query can return Demand data). To overcome this limitation it is possible to define multiple DCCs. Each configuration will define a different, but complete set of data access queries. EMarketOffer can use only one DCC at a time, which together with the data files loaded from the Inputs files directory, fully determine EMarketOffer's run-time data environment.

The Database Connection

A Database Connection is a set of data that describes the addressing, technical and security details required to a specific database on a specific database server. The details are combined in to a specific string format and used to access the required data. A DCC must contain one connection string for every database to be addressed in the configuration.


NOTE: Only one Connection per server is required in DCC. Therefore if all your data is stored in the same database then all queries required to access data can use the same Connection.

Source Data Administration Window

Access

The Data Sources option in the Main Window File Menu.

Purpose

To manage Database Connection Configurations (DCC).

Features

Feature Purpose
Database Connections Configuration Selector
To set the Current DCC from a drop down box of all currently available DCCs.
Open configuration Button
Opens the DCC Window for the selected configuration
New Configuration Button
Opens the New DCC Window Dialogue
Use Grid File Inputs Check Box
When checked (default) EMarketOffer processes Transmission System files in the Inputs/Grid sub-folder
Grid File Inputs Status Button
Opens the Grid File Inputs Status Window to show which Transmission Systems files are currently being used and any associated loading errors
Refresh All Cached Data Button
Reloads all cached data (from file and database)

The Grid File Inputs Station Window

Purpose

Details the files currently being used to load Constraints data and any associated loading errors. The Window can also be used to access and reload external grid files.

Components and Features

Component Feature Purpose
Control Panel
Reset Grid Inputs Button
Reloads the Constraints data files (allows you to load modified or replaced Transmission System files without having to restart EMarketOffer)
Open Grid Files Input Directory Button
Opens a standard Windows file directory window \Inputs\Grid for quick access to Transmission System files
Status Panel
External File Types Loaded List
Lists type of external transmission systems files loaded (in the above example the EM6 Constraints Change file type has been loaded)
Loading Error List
List the types of errors found when attempting to load files line by line. Errors are listed by re-ratings or Group Constraint groupings a total of each is provided. Errors text for each loading failure are designed to be self-explanatory
Setup Error List
Lists the errors when attempting to create a consistent set of Constraints after each line has been loaded